CVE-2020-12007
CRITICAL9.8

A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.

mitsubishielectric / mc_works+10
Network
Published Jul 16, 2020
CVE-2020-12011
CRITICAL9.8

A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior.

mitsubishielectric / mc_works+10
Network
Published Jul 16, 2020
CVE-2022-23128
CRITICAL9.8

Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.

iconics / analytix+4
Network
Published Jan 21, 2022
CVE-2022-33318
CRITICAL9.8

Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.

iconics / genesis64+2
Network
Published Jul 20, 2022
CVE-2020-12013
CRITICAL9.1

A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.

mitsubishielectric / mc_works32+10
Network
Published Jul 16, 2020
CVE-2022-33319
HIGH8.2

Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.

iconics / genesis64+2
Network
Published Jul 20, 2022
CVE-2022-33317
HIGH7.8

Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.

iconics / genesis64+2
Local
Published Jul 20, 2022
CVE-2024-7587
HIGH7.8

Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.

iconics / genesis64+1
Local
Published Oct 22, 2024
CVE-2022-33315
HIGH7.8

Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.

iconics / genesis64+2
Local
Published Jul 20, 2022
CVE-2022-33320
HIGH7.8

Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.

iconics / genesis64+2
Local
Published Jul 20, 2022
CVE-2021-27041
HIGH7.8

A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code

autodesk / advance_steel+46
Local
Published Jun 25, 2021
CVE-2022-33316
HIGH7.8

Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.

iconics / genesis64+2
Local
Published Jul 20, 2022
CVE-2020-12015
HIGH7.5

A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.

mitsubishielectric / mc_works+10
Network
Published Jul 16, 2020
CVE-2022-29834
HIGH7.5

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen.

iconics / genesis64+1
Network
Published Jul 20, 2022
CVE-2020-12009
HIGH7.5

A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.

mitsubishielectric / mc_works+10
Network
Published Jul 16, 2020
CVE-2022-40264
MEDIUM6.3

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker.

iconics / genesis64
Local
Published Dec 14, 2022
CVE-2022-23130
MEDIUM5.9

Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64, ICONICS Suite, MC Works64, or GENESIS32 and execute commands against the database from GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.

iconics / genesis64+2
Adjacent
Published Jan 21, 2022
CVE-2022-23129
MEDIUM5.5

Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.

iconics / genesis64+1
Local
Published Jan 21, 2022
CVE-2021-27040
LOW3.3

A maliciously crafted DWG file can be forced to read beyond allocated boundaries when parsing the DWG file. This vulnerability can be exploited to execute arbitrary code.

autodesk / advance_steel+42
Local
Published Jun 25, 2021