CVEInsight.
TrendingZero-DayExploreBrowseSearchSaved
CVEInsight.

Free vulnerability intelligence for developers, security teams, and researchers. Data sourced from public databases for informational purposes only.

Explore

HomeTrendingZero-Day WatchAttack TypesBrowse CVEsSearch

Legal

Privacy PolicyTerms of ServiceData Disclaimer

© 2026CVEInsight. For informational use only — not a substitute for professional security advice.

CVE data sourced from NVD / NIST & public disclosures.

schneider-electric

modicon_m340_bmxp3420302h_firmware

14 known vulnerabilities · sorted by CVSS score

CVE-2018-7241
CRITICAL9.8

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2018-7760
CRITICAL9.8

An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2018-7761
CRITICAL9.8

A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2018-7242
CRITICAL9.8

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2022-37300
CRITICAL9.8

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).

schneider-electric / ecostruxure_control_expert+35
Network
Published Sep 12, 2022
CVE-2022-45789
HIGH8.1

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)

schneider-electric / ecostruxure_control_expert+36
Network
Published Jan 31, 2023
CVE-2023-6408
HIGH8.1

CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.

schneider-electric / modicon_m340_bmxp341000_firmware+45
Network
Published Feb 14, 2024
CVE-2018-7759
HIGH7.5

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2022-0222
HIGH7.5

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24)

schneider-electric / modicon_m340_bmxp341000_firmware+13
Network
Published Nov 22, 2022
CVE-2018-7762
HIGH7.5

A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2022-45788
HIGH7.5

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)

schneider-electric / ecostruxure_control_expert+54
Network
Published Jan 30, 2023
CVE-2021-22786
HIGH7.5

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)

schneider-electric / modicon_m340_bmxp341000_firmware+40
Network
Published Feb 1, 2023
CVE-2015-6461
MEDIUM5.4

Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.

schneider-electric / bmxnoc0401_firmware+10
Network
Published Mar 21, 2019
CVE-2015-6462
MEDIUM5.4

Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.

schneider-electric / bmxnoc0401_firmware+10
Network
Published Mar 21, 2019