7 known vulnerabilities · sorted by CVSS score

CVE-2023-46141
CRITICAL9.8

Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.

phoenixcontact / automationworx_software_suite+17
Network
Published Dec 14, 2023
CVE-2019-12871
HIGH8.8

An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.

phoenixcontact / automationworx_software_suite
Network
Published Jun 24, 2019
CVE-2019-12869
HIGH8.8

An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-Of-Bounds Read, Information Disclosure, and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.

phoenixcontact / automationworx_software_suite
Network
Published Jun 24, 2019
CVE-2019-12870
HIGH8.8

An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Uninitialized Pointer and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.

phoenixcontact / automationworx_software_suite
Network
Published Jun 24, 2019
CVE-2022-3461
HIGH7.8

In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.

phoenixcontact / automationworx_software_suite
Local
Published Nov 15, 2022
CVE-2022-3737
HIGH7.8

In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.

phoenixcontact / automationworx_software_suite
Local
Published Nov 15, 2022
CVE-2023-46143
HIGH7.5

Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.

phoenixcontact / automationworx_software_suite+17
Network
Published Dec 14, 2023