CVEInsight.
TrendingZero-DayExploreBrowseSearchSaved
CVEInsight.

Free vulnerability intelligence for developers, security teams, and researchers. Data sourced from public databases for informational purposes only.

Explore

HomeTrendingZero-Day WatchAttack TypesBrowse CVEsSearch

Legal

Privacy PolicyTerms of ServiceData Disclaimer

© 2026CVEInsight. For informational use only — not a substitute for professional security advice.

CVE data sourced from NVD / NIST & public disclosures.

Search Vulnerabilities

 Software

Searching vulnerabilities affecting “schneider-electric”

205 vulnerabilities found for “schneider-electric”

Page 1 of 11

CVE-2024-6528
MEDIUM5.4

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

schneider-electric / modicon_m241_firmware+4
Network
Published Jul 11, 2024
Page 1 of 11
CVE-2022-32513
CRITICAL9.8

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

schneider-electric / 5500ac2_firmware+5
Network
Published Jan 30, 2023
CVE-2022-32514
CRITICAL9.8

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

schneider-electric / 5500ac2_firmware+5
Network
Published Jan 30, 2023
CVE-2022-2988
MEDIUM4.3

A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)

schneider-electric / ecostruxure_machine_expert_-_hvac+1
Network
Published Jan 30, 2023
CVE-2022-0222
HIGH7.5

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24)

schneider-electric / modicon_m340_bmxp341000_firmware+13
Network
Published Nov 22, 2022
CVE-2021-22699
HIGH7.5

Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.

schneider-electric / modicon_m241_firmware+1
Network
Published May 26, 2021
CVE-2020-7487
CRITICAL9.8

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.

schneider-electric / ecostruxure_machine_expert+6
Network
Published Apr 22, 2020
CVE-2020-7488
HIGH7.5

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.

schneider-electric / ecostruxure_machine_expert+6
Network
Published Apr 22, 2020
CVE-2019-6826
HIGH7.8

A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product.

schneider-electric / somachine_hvac
Local
Published Sep 17, 2019
CVE-2019-6820
HIGH8.2

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2

schneider-electric / modicon_m100_firmware+11
Network
Published May 22, 2019
CVE-2018-8872
HIGH8.1

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.

schneider-electric / triconex_tricon_mp_3008_firmware
Network
Published May 4, 2018
CVE-2018-7522
MEDIUM6.7

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.

schneider-electric / triconex_tricon_mp_3008_firmware
Local
Published May 4, 2018
CVE-2018-7760
CRITICAL9.8

An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2018-7759
HIGH7.5

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2018-7758
MEDIUM6.5

A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number.

schneider-electric / micom_p141_firmware+22
Adjacent
Published Apr 18, 2018
CVE-2018-7242
CRITICAL9.8

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2018-7241
CRITICAL9.8

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.

schneider-electric / bmxnor0200_firmware+59
Network
Published Apr 18, 2018
CVE-2017-9965
MEDIUM5.8

An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.

schneider-electric / pelco_videoxpert
Network
Published Jan 2, 2018
CVE-2017-9966
HIGH7.1

A privilege escalation vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. By replacing certain files, an unauthorized user can obtain system privileges and the inserted code would execute at an elevated privilege level.

schneider-electric / pelco_videoxpert
Network
Published Jan 2, 2018
CVE-2017-9964
MEDIUM6.9

A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack.

schneider-electric / pelco_videoxpert
Network
Published Jan 2, 2018