CVE-2025-41693
MEDIUM4.3

A low privileged remote attacker can use the ssh feature to execute commands directly after login. The process stays open and uses resources which leads to a reduced performance of the management functions. Switching functionality is not affected.

phoenixcontact / fl_switch_2708_pn_firmware+68
Network
Published Dec 9, 2025
Page 1 of 5
CVE-2025-41695
HIGH7.1

An XSS vulnerability in dyn_conn.php can be used by an unauthenticated remote attacker to trick an authenticated user to send a manipulated POST request to the device in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user.

phoenixcontact / fl_nat_2008_firmware+68
Network
Published Dec 9, 2025
CVE-2025-41697
MEDIUM6.8

An attacker can use an undocumented UART port on the PCB as a side-channel to get root access e.g. with the credentials obtained from CVE-2025-41692.

phoenixcontact / fl_switch_2708_pn_firmware+68
Physical
Published Dec 9, 2025
CVE-2025-41694
MEDIUM6.5

A low privileged remote attacker can run the webshell with an empty command containing whitespace. The server will then block until it receives more data, resulting in a DoS condition of the websserver.

phoenixcontact / fl_switch_2708_pn_firmware+68
Network
Published Dec 9, 2025
CVE-2025-41696
MEDIUM4.6

An attacker can use an undocumented UART port on the PCB as a side-channel with the user hardcoded credentials obtained from CVE-2025-41692 to gain read access to parts of the filesystem of the device.

phoenixcontact / fl_switch_2708_pn_firmware+68
Physical
Published Dec 9, 2025
CVE-2025-41692
MEDIUM6.8

A high privileged remote attacker with admin privileges for the webUI can brute-force the "root" and "user" passwords of the underlying OS due to a weak password generation algorithm.

phoenixcontact / fl_switch_2708_pn_firmware+68
Network
Published Dec 9, 2025
CVE-2025-41746
HIGH7.1

An XSS vulnerability in pxc_portSecCfg.php can be used by an unauthenticated remote attacker to trick an authenticated user to send a manipulated POST request to the device in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user.

phoenixcontact / fl_switch_2406-2sfx_pn_firmware+68
Network
Published Dec 9, 2025
CVE-2025-41745
HIGH7.1

An XSS vulnerability in pxc_portCntr2.php can be used by an unauthenticated remote attacker to trick an authenticated user to send a manipulated POST request to the device in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user.

phoenixcontact / fl_nat_2008_firmware+68
Network
Published Dec 9, 2025
CVE-2023-46144
MEDIUM6.5

A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.

phoenixcontact / axc_f_1152_firmware+8
Network
Published Dec 14, 2023
CVE-2023-46142
HIGH8.8

A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.

phoenixcontact / axc_f_1152_firmware+8
Network
Published Dec 14, 2023
CVE-2022-29897
CRITICAL9.1

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the traceroute utility integrated in the WebUI to execute arbitrary code with root privileges on the OS due to an improper input validation in all versions of the firmware.

phoenixcontact / rad-ism-900-en-bd_firmware+2
Network
Published May 11, 2022
CVE-2022-29898
CRITICAL9.1

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.

phoenixcontact / rad-ism-900-en-bd_firmware+2
Network
Published May 11, 2022
CVE-2022-22509
HIGH8.8

In Phoenix Contact FL SWITCH Series 2xxx in version 3.00 an incorrect privilege assignment allows an low privileged user to enable full access to the device configuration.

phoenixcontact / fl_switch_2005_firmware+64
Network
Published Feb 2, 2022
CVE-2021-34570
HIGH7.5

Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests.

phoenixcontact / plcnext_technology_starterkit_firmware+5
Network
Published Sep 27, 2021
CVE-2021-21003
MEDIUM5.3

In Phoenix Contact FL SWITCH SMCS series products in multiple versions fragmented TCP-Packets may cause a Denial of Service of Web-, SNMP- and ICMP-Echo services. The switching functionality of the device is not affected.

phoenixcontact / fl_switch_smcs_16tx_firmware+14
Network
Published Jun 25, 2021
CVE-2021-21004
HIGH7.4

In Phoenix Contact FL SWITCH SMCS series products in multiple versions an attacker may insert malicious code via LLDP frames into the web-based management which could then be executed by the client.

phoenixcontact / fl_switch_smcs_16tx_firmware+14
Adjacent
Published Jun 25, 2021
CVE-2021-21005
HIGH7.5

In Phoenix Contact FL SWITCH SMCS series products in multiple versions if an attacker sends a hand-crafted TCP-Packet with the Urgent-Flag set and the Urgent-Pointer set to 0, the network stack will crash. The device needs to be rebooted afterwards.

phoenixcontact / fl_switch_smcs_16tx_firmware+14
Network
Published Jun 25, 2021
CVE-2019-9743
HIGH8.8

An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices. Command injection can occur in the WebHMI component.

phoenixcontact / rad-80211-xd\/hp-bus_firmware+1
Network
Published Mar 26, 2019
CVE-2018-5441
HIGH7.8

An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages.

phoenixcontact / mguard_centerport_firmware+22
Local
Published Jan 30, 2018
CVE-2017-5753
MEDIUM5.6

Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.

intel / core_i5+999
Local
Published Jan 4, 2018