A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
AI analysis not yet available
Plain-English explanation, risk summary, and remediation steps will appear here once AI analysis is complete.
No Fix Known
No patch has been released yet. Apply workarounds or mitigations where available.
| Vendor | Product | Versions | Fixed In |
|---|---|---|---|
| siemens | scalance_xc-200_firmware | 5.2.4 | - |
| siemens | scalance_xf-200_firmware | 5.2.4 |
Published
CVE disclosed publicly
Last Modified
Most recent update
Indexed to CVEInsight
Added to this platform
AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N
8
Affected Products
4
References
siemens / scalance_xc-200_firmware
| - |
| siemens | scalance_xp-200_firmware | 5.2.4 | - |
| siemens | scalance_x-200irt_firmware | - | - |
| siemens | scalance_xb-200_firmware | 5.2.4 | - |
| siemens | scalance_xr-300wg_firmware | 4.1.3 | - |
| siemens | scalance_x-300_firmware | 4.1.3 | - |
| siemens | scalance_xr-300_firmware | 4.1.3 | - |
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N
Exploitability
Impact