A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
AI analysis not yet available
Plain-English explanation, risk summary, and remediation steps will appear here once AI analysis is complete.
No Fix Known
No patch has been released yet. Apply workarounds or mitigations where available.
| Vendor | Product | Versions | Fixed In |
|---|---|---|---|
| siemens | sinumerik_828d_firmware | 4.7 | - |
| siemens | sinumerik_840d_sl_firmware | 4.7 |
Published
CVE disclosed publicly
Last Modified
Most recent update
Indexed to CVEInsight
Added to this platform
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
3
Affected Products
4
References
siemens / sinumerik_828d_firmware
| - |
| siemens | sinumerik_840d_sl_firmware | 4.8 | - |
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
Exploitability
Impact